Document parameter "degraded_monitoring_timeout"
Also ensure it can be reloaded.
This commit is contained in:
@@ -1435,6 +1435,9 @@ and the primary node is unavailable (but is later restarted):
|
|||||||
[2017-08-29 11:00:45] [NOTICE] reconnected to upstream node 1 after 68 seconds, resuming monitoring
|
[2017-08-29 11:00:45] [NOTICE] reconnected to upstream node 1 after 68 seconds, resuming monitoring
|
||||||
[2017-08-29 11:00:57] [INFO] node "node2" (node ID: 2) monitoring upstream node "node1" (node ID: 1) in normal state (automatic failover disabled)
|
[2017-08-29 11:00:57] [INFO] node "node2" (node ID: 2) monitoring upstream node "node1" (node ID: 1) in normal state (automatic failover disabled)
|
||||||
|
|
||||||
|
By default, `repmgrd` will continue in degraded monitoring mode indefinitely.
|
||||||
|
However a timeout (in seconds) can be set with `degraded_monitoring_timeout`.
|
||||||
|
|
||||||
### `repmgrd` log rotation
|
### `repmgrd` log rotation
|
||||||
|
|
||||||
To ensure the current `repmgrd` logfile does not grow indefinitely, configure
|
To ensure the current `repmgrd` logfile does not grow indefinitely, configure
|
||||||
|
|||||||
10
configfile.c
10
configfile.c
@@ -943,7 +943,6 @@ reload_config(t_configuration_options *orig_options)
|
|||||||
config_changed = true;
|
config_changed = true;
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
/* conninfo */
|
/* conninfo */
|
||||||
if (strcmp(orig_options->conninfo, new_options.conninfo) != 0)
|
if (strcmp(orig_options->conninfo, new_options.conninfo) != 0)
|
||||||
{
|
{
|
||||||
@@ -962,6 +961,15 @@ reload_config(t_configuration_options *orig_options)
|
|||||||
PQfinish(conn);
|
PQfinish(conn);
|
||||||
}
|
}
|
||||||
|
|
||||||
|
/* degraded_monitoring_timeout */
|
||||||
|
if (orig_options->degraded_monitoring_timeout != new_options.degraded_monitoring_timeout)
|
||||||
|
{
|
||||||
|
orig_options->degraded_monitoring_timeout = new_options.degraded_monitoring_timeout;
|
||||||
|
log_info(_("\"degraded_monitoring_timeout\" is now \"%i\""), new_options.degraded_monitoring_timeout);
|
||||||
|
|
||||||
|
config_changed = true;
|
||||||
|
}
|
||||||
|
|
||||||
/* event_notification_command */
|
/* event_notification_command */
|
||||||
if (strcmp(orig_options->event_notification_command, new_options.event_notification_command) != 0)
|
if (strcmp(orig_options->event_notification_command, new_options.event_notification_command) != 0)
|
||||||
{
|
{
|
||||||
|
|||||||