<refentry id="repmgr-standby-switchover">
<indexterm>
<primary>repmgr standby switchover</primary>
</indexterm>
<refmeta>
<refentrytitle>repmgr standby switchover</refentrytitle>
</refmeta>
<refnamediv>
<refname>repmgr standby switchover</refname>
<refpurpose>promote a standby to primary and demote the existing primary to a standby</refpurpose>
</refnamediv>
<refsect1>
<title>Description</title>
<para>
Promotes a standby to primary and demotes the existing primary to a standby.
This command must be run on the standby to be promoted, and requires a
passwordless SSH connection to the current primary.
</para>
<para>
If other standbys are connected to the demotion candidate, &repmgr; can instruct
these to follow the new primary if the option <literal>--siblings-follow</literal>
is specified. This requires a passwordless SSH connection between the promotion
candidate (new primary) and the standbys attached to the demotion candidate
(existing primary).
</para>
<note>
<para>
Performing a switchover is a non-trivial operation. In particular it
relies on the current primary being able to shut down cleanly and quickly.
&repmgr; will attempt to check for potential issues but cannot guarantee
a successful switchover.
</para>
</note>
</refsect1>
<refsect1>
<title>Options</title>
<variablelist>
<varlistentry>
<term><option>--always-promote</option></term>
<listitem>
<para>
Promote standby to primary, even if it is behind original primary
(original primary will be shut down in any case).
</para>
</listitem>
</varlistentry>
<varlistentry>
<term><option>--dry-run</option></term>
<listitem>
<para>
Check prerequisites but don't actually execute a switchover.
</para>
<important>
<para>
Success of <option>--dry-run</option> does not imply the switchover will
complete successfully, only that
the prerequisites for performing the operation are met.
</para>
</important>
</listitem>
</varlistentry>
<varlistentry>
<term><option>-F</option></term>
<term><option>--force</option></term>
<listitem>
<para>
Ignore warnings and continue anyway.
</para>
<para>
Specifically, if a problem is encountered when shutting down the current primary,
using <option>-F/--force</option> will cause &repmgr; to continue by promoting
the standby to be the new primary, and if <option>--siblings-follow</option> is
specified, attach any other standbys to the new primary.
</para>
</listitem>
</varlistentry>
<varlistentry>
<term><option>--force-rewind</option></term>
<listitem>
<para>
Use <application>pg_rewind</application> to reintegrate the old primary if necessary
(PostgreSQL 9.5 and later).
</para>
</listitem>
</varlistentry>
<varlistentry>
<term><option>-R</option></term>
<term><option>--remote-user</option></term>
<listitem>
<para>
System username for remote SSH operations (defaults to local system user).
</para>
</listitem>
</varlistentry>
<varlistentry>
<term><option>--siblings-follow</option></term>
<listitem>
<para>
Have standbys attached to the old primary follow the new primary.
</para>
</listitem>
</varlistentry>
</variablelist>
</refsect1>
<refsect1>
<title>Execution</title>
<para>
Execute with the <literal>--dry-run</literal> option to test the switchover as far as
possible without actually changing the status of either node.
</para>
<para>
<application>repmgrd</application> should not be active on any nodes while a switchover is being
executed. This restriction may be lifted in a later version.
</para>
<para>
External database connections, e.g. from an application, should not be permitted while
the switchover is taking place. In particular, active transactions on the primary
can potentially disrupt the shutdown process.
</para>
</refsect1>
<refsect1>
<title>Event notifications</title>
<para>
<literal>standby_switchover</literal> and <literal>standby_promote</literal>
<link linkend="event-notifications">event notifications</link> will be generated for the new primary,
and a <literal>node_rejoin</literal> event notification for the former primary (new standby).
</para>
<para>
If using an event notification script, <literal>standby_switchover</literal>
will populate the placeholder parameter <literal>%p</literal> with the node ID of
the former primary.
</para>
</refsect1>
<refsect1>
<title>Exit codes</title>
<para>
Following exit codes can be emitted by <literal>repmgr standby switchover</literal>:
</para>
<variablelist>
<varlistentry>
<term><option>SUCCESS (0)</option></term>
<listitem>
<para>
The switchover completed successfully.
</para>
</listitem>
</varlistentry>
<varlistentry>
<term><option>ERR_SWITCHOVER_FAIL (18)</option></term>
<listitem>
<para>
The switchover could not be executed.
</para>
</listitem>
</varlistentry>
<varlistentry>
<term><option>ERR_SWITCHOVER_INCOMPLETE (22)</option></term>
<listitem>
<para>
The switchover was executed but a problem was encountered.
Typically this means the former primary could not be reattached
as a standby.
</para>
</listitem>
</varlistentry>
</variablelist>
</refsect1>
<refsect1>
<title>See also</title>
<para>
For more details see the section <xref linkend="performing-switchover">.
</para>
</refsect1>
</refentry>