Merge pull request #133 from martinmarques/fix-standby-follows-other-node-repmgrd-fails

Fix standby follows other node repmgrd fails
This commit is contained in:
Martín Marqués
2015-12-29 13:25:09 -03:00

View File

@@ -657,7 +657,6 @@ standby_monitor(void)
char last_wal_standby_received[MAXLEN];
char last_wal_standby_applied[MAXLEN];
char last_wal_standby_applied_timestamp[MAXLEN];
bool last_wal_standby_received_gte_applied;
char sqlquery[QUERY_STR_LEN];
XLogRecPtr lsn_master;
@@ -946,8 +945,7 @@ standby_monitor(void)
/* Get local xlog info */
sqlquery_snprintf(sqlquery,
"SELECT CURRENT_TIMESTAMP, pg_last_xlog_receive_location(), "
"pg_last_xlog_replay_location(), pg_last_xact_replay_timestamp(), "
"pg_last_xlog_receive_location() >= pg_last_xlog_replay_location()");
"pg_last_xlog_replay_location(), pg_last_xact_replay_timestamp()");
res = PQexec(my_local_conn, sqlquery);
if (PQresultStatus(res) != PGRES_TUPLES_OK)
@@ -963,45 +961,8 @@ standby_monitor(void)
strncpy(last_wal_standby_applied, PQgetvalue(res, 0, 2), MAXLEN);
strncpy(last_wal_standby_applied_timestamp, PQgetvalue(res, 0, 3), MAXLEN);
last_wal_standby_received_gte_applied = (strcmp(PQgetvalue(res, 0, 4), "t") == 0)
? true
: false;
PQclear(res);
/*
* Check that last WAL received is greater or equal to last WAL applied
*
* This situation can occur when the standby is no longer connected to
* the upstream node; in this case repmgrd should terminate itself
* as the node may no longer be capable of being promoted or following
* a new upstream node
*
* XXX check if we should (optionally) adopt other strategies to handle
* this situation
*/
if(last_wal_standby_received_gte_applied == false)
{
PQExpBufferData errmsg;
initPQExpBuffer(&errmsg);
appendPQExpBuffer(&errmsg,
/* XXX improve message */
_("This node is no longer connected to its upstream node - terminating"));
log_crit("%s\n", errmsg.data);
create_event_record(master_conn,
&local_options,
local_options.node,
"repmgrd_monitor",
false,
errmsg.data);
// XXX use better code
terminate(ERR_MONITORING_FAIL);
}
/* Get master xlog info */
sqlquery_snprintf(sqlquery, "SELECT pg_catalog.pg_current_xlog_location()");