mirror of
https://github.com/EnterpriseDB/repmgr.git
synced 2026-03-22 22:56:29 +00:00
Update BDR documentation
This commit is contained in:
@@ -35,11 +35,18 @@ will use PgBouncer.
|
||||
The proxy server / connection poolers must not be installed on the database
|
||||
servers.
|
||||
|
||||
For this example, it's assumed password-less SSH connections are available
|
||||
from the PostgreSQL servers to the servers where PgBouncer runs, and
|
||||
that the user on those servers has permission to alter the PgBouncer
|
||||
configuration files.
|
||||
|
||||
PostgreSQL connections must be possible between each node, and each node
|
||||
must be able to connect to each PgBouncer instance.
|
||||
|
||||
|
||||
Configuration
|
||||
-------------
|
||||
|
||||
|
||||
Sample configuration for `repmgr.conf`:
|
||||
|
||||
node_id=1
|
||||
@@ -51,14 +58,16 @@ Sample configuration for `repmgr.conf`:
|
||||
event_notification_command='/path/to/bdr-pgbouncer.sh %n %e %s "%c" "%a" >> /tmp/bdr-failover.log 2>&1'
|
||||
|
||||
# repmgrd options
|
||||
reconnect_attempts=5
|
||||
reconnect_interval=6
|
||||
monitor_interval_secs=5
|
||||
reconnect_attempts=6
|
||||
reconnect_interval=5
|
||||
|
||||
Adjust settings as appropriate; copy and adjust for the second node (particularly
|
||||
the values `node_id`, `node_name` and `conninfo`).
|
||||
|
||||
Note that the values provided for the `conninfo` string must be valid for
|
||||
connections from *both* nodes in the cluster.
|
||||
connections from *both* nodes in the cluster. The database must be the BDR
|
||||
database.
|
||||
|
||||
If defined, `event_notifications` will restrict execution of `event_notification_command`
|
||||
to the specified events.
|
||||
@@ -68,6 +77,17 @@ of reconfiguring the proxy server/ connection pooler. It is fully user-definable
|
||||
a sample implementation is documented below.
|
||||
|
||||
|
||||
repmgr user permissions
|
||||
-----------------------
|
||||
|
||||
`repmgr` will create an extension in the BDR database containing objects
|
||||
for administering `repmgr` metadata. The user defined in the `conninfo`
|
||||
setting must be able to access all objects. Additionally, superuser permissions
|
||||
are required to install the `repmgr` extension. The easiest way to do this
|
||||
is create the `repmgr` user as a superuser, however if this is not
|
||||
desirable, the `repmgr` user can be created as a normal user and a
|
||||
superuser specified with `--superuser` when registering a BDR node.
|
||||
|
||||
repmgr setup
|
||||
------------
|
||||
|
||||
@@ -95,9 +115,9 @@ At this point the meta data for both nodes has been created; executing
|
||||
|
||||
$ repmgr -f /etc/repmgr.conf cluster show
|
||||
ID | Name | Role | Status | Upstream | Connection string
|
||||
----+-------+------+-----------+----------+-----------------------------------------------------
|
||||
1 | node1 | bdr | * running | | host=node1 dbname=bdrtest user=repmgr
|
||||
2 | node2 | bdr | * running | | host=node2 dbname=bdrtest user=repmgr
|
||||
----+-------+------+-----------+----------+--------------------------------------------------------
|
||||
1 | node1 | bdr | * running | | host=node1 dbname=bdrtest user=repmgr connect_timeout=2
|
||||
2 | node2 | bdr | * running | | host=node2 dbname=bdrtest user=repmgr connect_timeout=2
|
||||
|
||||
Additionally it's possible to see a log of significant events; so far
|
||||
this will only record the two node registrations (in reverse chronological order):
|
||||
@@ -149,13 +169,94 @@ both nodes; these will need to be adjusted for your local environment of course
|
||||
(ideally the scripts would be maintained as templates and generated by some
|
||||
kind of provisioning system).
|
||||
|
||||
The script performs following steps:
|
||||
|
||||
- pauses PgBouncer on all nodes
|
||||
- recreates the PgBouncer configuration file on each node using the information
|
||||
provided by `repmgrd` (mainly the `conninfo` string) to configure PgBouncer
|
||||
to point to the remaining node
|
||||
- reloads the PgBouncer configuration
|
||||
- resumes PgBouncer
|
||||
|
||||
From that point, any connections to PgBouncer on the failed BDR node will be redirected
|
||||
to the active node.
|
||||
|
||||
|
||||
repmgrd
|
||||
-------
|
||||
|
||||
Node failover
|
||||
-------------
|
||||
|
||||
|
||||
Node monitoring and failover
|
||||
----------------------------
|
||||
|
||||
At the intervals specified by `monitor_interval_secs` in `repmgr.conf`, `repmgrd`
|
||||
will ping each node to check if it's available. If a node isn't available,
|
||||
`repmgrd` will enter failover mode and check `reconnect_attempts` times
|
||||
at intervals of `reconnect_interval` to confirm the node is definitely unreachable.
|
||||
This buffer period is necessary to avoid false positives caused by transient
|
||||
network outages.
|
||||
|
||||
If the node is still unavailable, `repmgrd` will enter failover mode and execute
|
||||
the script defined in `event_notification_command`; an entry will be logged
|
||||
in the `repmgr.events` table and `repmgrd` will (unless otherwise configured)
|
||||
resume monitoring of the node in "degraded" mode until it reappears.
|
||||
|
||||
`repmgrd` logfile output during a failover event will look something like this
|
||||
one one node (usually the node which has failed, here "node2"):
|
||||
|
||||
...
|
||||
[2017-07-27 21:08:39] [INFO] starting continuous BDR node monitoring
|
||||
[2017-07-27 21:08:39] [INFO] monitoring BDR replication status on node "node2" (ID: 2)
|
||||
[2017-07-27 21:08:55] [INFO] monitoring BDR replication status on node "node2" (ID: 2)
|
||||
[2017-07-27 21:09:11] [INFO] monitoring BDR replication status on node "node2" (ID: 2)
|
||||
[2017-07-27 21:09:23] [WARNING] unable to connect to node node2 (ID 2)
|
||||
[2017-07-27 21:09:23] [INFO] checking state of node 2, 0 of 5 attempts
|
||||
[2017-07-27 21:09:23] [INFO] sleeping 1 seconds until next reconnection attempt
|
||||
[2017-07-27 21:09:24] [INFO] checking state of node 2, 1 of 5 attempts
|
||||
[2017-07-27 21:09:24] [INFO] sleeping 1 seconds until next reconnection attempt
|
||||
[2017-07-27 21:09:25] [INFO] checking state of node 2, 2 of 5 attempts
|
||||
[2017-07-27 21:09:25] [INFO] sleeping 1 seconds until next reconnection attempt
|
||||
[2017-07-27 21:09:26] [INFO] checking state of node 2, 3 of 5 attempts
|
||||
[2017-07-27 21:09:26] [INFO] sleeping 1 seconds until next reconnection attempt
|
||||
[2017-07-27 21:09:27] [INFO] checking state of node 2, 4 of 5 attempts
|
||||
[2017-07-27 21:09:27] [INFO] sleeping 1 seconds until next reconnection attempt
|
||||
[2017-07-27 21:09:28] [WARNING] unable to reconnect to node 2 after 5 attempts
|
||||
[2017-07-27 21:09:28] [NOTICE] setting node record for node 2 to inactive
|
||||
[2017-07-27 21:09:28] [INFO] executing notification command for event "bdr_failover"
|
||||
[2017-07-27 21:09:28] [DETAIL] command is:
|
||||
/path/to/bdr-pgbouncer.sh 2 bdr_failover 1 "host=host=node1 dbname=bdrtest user=repmgr connect_timeout=2" "node1"
|
||||
[2017-07-27 21:09:28] [INFO] node 'node2' (ID: 2) detected as failed; next available node is 'node1' (ID: 1)
|
||||
[2017-07-27 21:09:28] [INFO] monitoring BDR replication status on node "node2" (ID: 2)
|
||||
[2017-07-27 21:09:28] [DETAIL] monitoring node "node2" (ID: 2) in degraded mode
|
||||
...
|
||||
|
||||
Output on the other node ("node1") during the same event will look like this:
|
||||
|
||||
[2017-07-27 21:08:35] [INFO] starting continuous BDR node monitoring
|
||||
[2017-07-27 21:08:35] [INFO] monitoring BDR replication status on node "node1" (ID: 1)
|
||||
[2017-07-27 21:08:51] [INFO] monitoring BDR replication status on node "node1" (ID: 1)
|
||||
[2017-07-27 21:09:07] [INFO] monitoring BDR replication status on node "node1" (ID: 1)
|
||||
[2017-07-27 21:09:23] [WARNING] unable to connect to node node2 (ID 2)
|
||||
[2017-07-27 21:09:23] [INFO] checking state of node 2, 0 of 5 attempts
|
||||
[2017-07-27 21:09:23] [INFO] sleeping 1 seconds until next reconnection attempt
|
||||
[2017-07-27 21:09:24] [INFO] checking state of node 2, 1 of 5 attempts
|
||||
[2017-07-27 21:09:24] [INFO] sleeping 1 seconds until next reconnection attempt
|
||||
[2017-07-27 21:09:25] [INFO] checking state of node 2, 2 of 5 attempts
|
||||
[2017-07-27 21:09:25] [INFO] sleeping 1 seconds until next reconnection attempt
|
||||
[2017-07-27 21:09:26] [INFO] checking state of node 2, 3 of 5 attempts
|
||||
[2017-07-27 21:09:26] [INFO] sleeping 1 seconds until next reconnection attempt
|
||||
[2017-07-27 21:09:27] [INFO] checking state of node 2, 4 of 5 attempts
|
||||
[2017-07-27 21:09:27] [INFO] sleeping 1 seconds until next reconnection attempt
|
||||
[2017-07-27 21:09:28] [WARNING] unable to reconnect to node 2 after 5 attempts
|
||||
[2017-07-27 21:09:28] [NOTICE] other node's repmgrd is handling failover
|
||||
[2017-07-27 21:09:28] [INFO] monitoring BDR replication status on node "node1" (ID: 1)
|
||||
[2017-07-27 21:09:28] [DETAIL] monitoring node "node2" (ID: 2) in degraded mode
|
||||
|
||||
This assumes only the PostgreSQL instance on "node2" has failed. In this case the
|
||||
`repmgrd` instance running on "node2" has performed the failover. However if
|
||||
the entire server becomes unavailable, `repmgrd` on "node1" will perform
|
||||
the failover.
|
||||
|
||||
|
||||
Node recovery
|
||||
@@ -166,3 +267,22 @@ a `bdr_recovery` event will be generated. This could potentially be used to
|
||||
reconfigure PgBouncer automatically to bring the node back into the available pool,
|
||||
however it would be prudent to manually verify the node's status before
|
||||
exposing it to the application.
|
||||
|
||||
If the failed node comes back up and connects correctly, output similar to this
|
||||
will be visible in the `repmgrd` log:
|
||||
|
||||
[2017-07-27 21:25:30] [DETAIL] monitoring node "node2" (ID: 2) in degraded mode
|
||||
[2017-07-27 21:25:46] [INFO] monitoring BDR replication status on node "node2" (ID: 2)
|
||||
[2017-07-27 21:25:46] [DETAIL] monitoring node "node2" (ID: 2) in degraded mode
|
||||
[2017-07-27 21:25:55] [INFO] active replication slot for node "node1" found after 1 seconds
|
||||
[2017-07-27 21:25:55] [NOTICE] node "node2" (ID: 2) has recovered after 986 seconds
|
||||
|
||||
|
||||
Shutdown of both nodes
|
||||
----------------------
|
||||
|
||||
If both PostgreSQL instances are shut down, `repmgrd` will try and handle the
|
||||
situation as gracefully as possible, though with no failover candidates available
|
||||
there's not much it can do. Should this case ever occur, we recommend shutting
|
||||
down `repmgrd` on both nodes and restarting it once the PostgreSQL instances
|
||||
are running properly.
|
||||
|
||||
Reference in New Issue