If a connection was provided for a database other than the "repmgr"
database, error was logged but execution continued, resulting in
the connection being finished twice.
Addresses GitHub #358.
"repmgr node check --archive-ready" is correct, however abbreviated
versions will be accepted by getopt_long() if they don't match
or partially match any other options.
Per report by "chaintng" in GitHub #355.
This makes comments stay aligned in most cases the conf file is
modified, and when indentation changes, it's easy to re-align
(by removing or adding a tab)
Signed-off-by: Martín Marqués <martin.marques@2ndquadrant.com>
This previously happened in the extension SQL code, which could
potentially cause replay problems if installing on a BDR cluster.
As this table is only required for streaming replication failover,
move the initialisation to "repmgr primary register".
Addresses GitHub #344 .
If --force-rewind is used in conjunction with "repmgr node rejoin",
any replication slots present on the source node will be copied too;
it's essential to remove these to prevent stale slots being extant
when the node starts up.
We do this at file system level *before* the server starts to minimize
the risk of any problems.
Addresses GitHub #334
The check was being carried out regardless of whether --copy-external-config-files
was specified, which means cloning will fail if no SSH connection is available.
Addresses GitHub #342
This bug was not detected before because most users work with the repmgr
user. For that reason, the repmgr schema is already in the search_path
by default.
Add the repmgr schema to the nodes table in the LEFT JOIN used for
cluster show (and in other places)
Signed-off-by: Martín Marqués <martin.marques@2ndquadrant.com>
The warning emitted gives the impression that monitoring data shouldn't
be written if there's no streaming replication, but we can and should
do this as long as we have a primary connection.
Explictly document this in the code.
Also remove an unused variable warning.